ASUS Portable Ultrasound Solution

ASUS Portable Ultrasound Series

ASUS Portable Ultrasound Series

High-quality handheld scanners for fast, reliable medical imaging

  • Google Play
  • App Store

Download ASUS Instant Guard app

LU700C Convex

64 mm

131 mm

  • Portable, smart imaging device

    Lightweight, wireless handheld unit seamlessly integrates with proprietary imaging system software.
  • Full functions and excellent image quality

    Models produce high-quality imagery across diverse scenarios.
  • Long battery life

    Up to four hours of continuous use from a single charge.
  • Intuitive interface and flexible image-management tools

    Easy-to-use device interface and robust software* enable a range of uses by medical professionals

ASUS Portable Ultrasound Series

ASUS Portable Ultrasound is a series of point-of-care ultrasound (POCUS) solutions, with compact, lightweight and portable designs, long battery life, high durability and wireless connectivity. They’re ideal for rapid, on-the-go diagnosis of a variety of conditions, with a selection of models designed for either on either humans or animals – or both. For human patients, ASUS Portable Ultrasound scanners can be used by clinicians on regular rounds, in ambulances on the move, during emergency-room procedures or for everyday training purposes.
Clinic

Clinic

Ambulances

Ambulances

Clinicians on regular rounds​

Clinicians on regular rounds​

Emergency-room​

Emergency-room​

Medical training

Medical training

ASUS Portable Ultrasound in Motion

ASUS Portable Ultrasound in Motion

  • Smart handheld scanners for fast, reliable medical imaging

    The compact and wireless ASUS Portable Ultrasound Series provides healthcare professionals with a comprehensive array of functions, exceptional scanned images, and energy efficiency. Click on the video to learn more about ASUS Portable Ultrasound devices.
  • User Guide

    Learn about the intuitive UI and extensive capabilities of ASUS Portable Ultrasound Devices in this step-by-step video.

ASUS Portable Ultrasound for Medical Care

LU700C Convex
LU700C Convex
Intended use General abdominal imaging, lungs, muscles and bones (traditional), muscles and bones (surface), peripheral arteries, and obstetrics and gynecology. General abdominal imaging, lungs, small organs (chest, thyroid), muscles and bones (traditional), muscles and bones (surface), and peripheral arteries. General abdominal imaging, lungs, small organs (chest, thyroid), muscles and bones (traditional), muscles and bones (surface), and peripheral arteries. General abdominal imaging, small organs, cardiac diagnosis, muscle and bone (traditional), muscle and bone (surface), and peripheral arteries. Abdomen Cardiac Endocavity
Frequency 2.0 –5.0 MHz 5.0 –10.0 MHz 4.5 –12.5 MHz 4.0 –8.0 MHz 1.7-3.7MHz 4-8.5MHz
FOV 60° N/A N/A 100° 90° 151°
Depth 25 cm 12 cm 12 cm 12 cm 18 cm 15 cm
Size 187 x 74 x 40 mm 178 x 74 x 40 mm 178 x 74 x 40 mm 190 x 74 x 40 mm 194 × 74 × 40 mm 370 x 74 x 40 mm
Weight 388g 357g 357g 340g 350g 412g
Operation B/M/CF/PW/PD
Image file JPEG/PNG/BMP/DICOM
Battery Rechargeable 6000 mAhLi-ion Battery, up to 4 hours.
Intended use General abdominal imaging, lungs, muscles and bones (traditional), muscles and bones (surface), peripheral arteries, and obstetrics and gynecology.
Frequency 2.0 –5.0 MHz
FOV 60°
Depth 25 cm
Size 187 x 74 x 40 mm
Weight 388g
Operation B/M/CF/PW/PD
Image file JPEG/PNG/BMP/DICOM
Battery Rechargeable 6000 mAhLi-ion Battery, up to 4 hours.
Intended use General abdominal imaging, lungs, small organs (chest, thyroid), muscles and bones (traditional), muscles and bones (surface), and peripheral arteries.
Frequency 5.0 –10.0 MHz
FOV N/A
Depth 12 cm
Size 178 x 74 x 40 mm
Weight 357g
Operation B/M/CF/PW/PD
Image file JPEG/PNG/BMP/DICOM
Battery Rechargeable 6000 mAhLi-ion Battery, up to 4 hours.
Intended use General abdominal imaging, lungs, small organs (chest, thyroid), muscles and bones (traditional), muscles and bones (surface), and peripheral arteries.
Frequency 4.5 - 12.5 MHz
FOV N/A
Depth 12 cm
Size 178 x 74 x 40 mm
Weight 357g
Operation B/M/CF/PW/PD
Image file JPEG/PNG/BMP/DICOM
Battery Rechargeable 6000 mAhLi-ion Battery, up to 4 hours.
Intended use General abdominal imaging, small organs, cardiac diagnosis, muscle and bone (traditional), muscle and bone (surface), and peripheral arteries.
Frequency 4.0 –8.0 MHz
FOV 100°
Depth 12 cm
Size 190x 74 x 40 mm
Weight 340g
Operation B/M/CF/PW/PD
Image file JPEG/PNG/BMP/DICOM
Battery Rechargeable 6000 mAhLi-ion Battery, up to 4 hours.
Intended use Abdomen Cardiac
Frequency 1.7-3.7MHz
FOV 90°
Depth 18 cm
Size 194 × 74 × 40 mm
Weight 350g
Operation B/M/CF/PW/PD
Image file JPEG/PNG/BMP/DICOM
Battery Rechargeable 6000 mAhLi-ion Battery, up to 4 hours.
Intended use Endocavity
Frequency 4-8.5MHz
FOV 151°
Depth 15 cm
Size 370 x 74 x 40 mm
Weight 412g
Operation B/M/CF/PW/PD
Image file JPEG/PNG/BMP/DICOM
Battery Rechargeable 6000 mAhLi-ion Battery, up to 4 hours.

* Availability depends on different regions.

ASUS Portable Ultrasound for Veterinary Care

The three ASUS portable ultrasound models are also suitable for use on animals, from small pets such as cats and dogs to large livestock, including cattle sheep and horses.

Click here to learn more

  • Small pets
  • Large livestock

ASUS Portable Ultrasound Glossory

M mode measurement

Ventricle Measure

  • LVIDd : Left ventricular internal diameter end diastole
  • LVIDs: Left ventricular internal diameter end systole
  • EDV: End diastolic volume, amount of blood in the ventricle during diastole
  • ESV: End systolic volume, amount of blood in ventricle after systole
  • EDVIndex: End-diastolic volume index, referred to as EDV corrected for BSA
  • ESVindex: End- systolic volume index
  • SV: Stroke volume, volume of blood pumped from the heart in one cycle of diastole and systole, is affected by Preload, contractility and Afterload
  • CO: Cardiac output, quantity of blood pumped per minute through the aorta and into the peripheral circulation, is proportional to (Arterial pressure / Total peripheral resistance)
  • EF: Ejection fraction, reflects the percentage of blood ejected from the ventricle
  • FS: Fractional shortening

OB calculations

  • GA: Gestational Age.
  • Fetal age: Conceptional age.
  • EFW: Estimated fetal weight.
  • AUA: Arithmetic ultrasound age.
  • DOC: Date of conception.
  • LMP: Last menstrual period.
  • EDD: Estimated due date.

In Early OB

  • CRL: Crown-rump length
  • GS: Gestational sac.

In Mid-late OB

  • AC: Abdominal circumference.
  • HC: Head circumference.
  • FL: Femur length.
  • BPD: Biparietal diameter.

References

  • Early OB calculations: Hadlock 1992. Fetal Crown-Rump Length: Reevaluation of Relation to Menstrual Age with High-Resolution Real-Time US.
  • Mid-late OB calculations: Hadlock 1984 Hadlock F.P, Deter R.L, Harrist R.B. and Park S.K, Estimating fetal age: computer-assisted analysis of multiple fetal growth parameters, Radiology, 152, pp 497-501, 1984
  • EFW equations: EFW by AC, BPD FL, and HC: Hadlock 1985 Hadlock F.P, Harrist R.B, Sharman R.S, Deter R.L, Park S.K, Estimation of fetal weight with the use of head, body, and femur measurements–a prospective study, Am.J.Obstet.Gynecol., 151, pp 333-337, 1985

PW mode measurement

The glossary of "Auto Measure"

  • HR (bpm):Heart rate
  • PSV (cm/s):Peak systolic velocity
  • EDV (cm/s):End diastolic velocity
  • PI:Pulsatility index (of Gosling)
     PI = (PSV–EDV)/MV
     MV (cm/s):Mean velocity
  • RI:Resistance index (of Pourcelot)
     RI = (PSV–EDV)/PSV
  • VTI (cm):Velocity-time integral
  • TAV Max (cm/s):The maximum of time-averaged velocity
  • S/B:The average RI of a cycle
  • SD:Systolic/Diastolic Ratio
     SD = PSV/EDV
  • ACCL (cm/s²):The acceleration index
     ACCL = (PSV – EDV)/ACCT
  • ACCT (s):The time from the lowest (EDV) to the highest (PSV)
  • VFM (ml/min):Volume flow per minute
  • VFC (ml):Volume flow per cycle
  • VFM Max (ml/min):The maximum of volume flow per minute
  • Diam (mm) :Diameter

The glossary of measure tool "PW V, T, HR"

  • T (s):Time
  • HR (bpm):Heart rate
  • Range (cm/s):The range of flow velocity

The glossary of measure tool "RI, S/D"

  • PSV (cm/s):Peak systolic velocity
  • EDV (cm/s):End diastolic velocity
  • S/D:Systolic/Diastolic Ratio
     SD = PSV/EDV
  • RI:Resistance index (of Poucelot)
     RI = (PSV–EDV)/PSV

The glossary of measure tool "PI"

  • PSV (cm/s):Peak systolic velocity
  • D (cm/s):End diastolic velocity
  • Area (cm²):Blood vessel cross-sectional area
  • Diam (mm):Diameter
  • PI:Pulsatility index (of Gosling)
     PI = (PSV–EDV)/MV
     MV (cm/s):Mean velocity
  • VFM Max (ml/min):The maximum of volume flow per minute
  • TAV Max (cm/s):The maximum of time-averaged velocity

The glossary of measure tool "VTI"

  • VTI (cm):Velocity-time integral

Cardiac measurement in B mode

  • BSA: Body Surface Area
     = (Height * Weight / 3600)^½
  • SV (ml): Stroke volume
     = EDV – ESV
  • SI (ml/m²): Stroke volume index
     = SV / BSA
  • CO (l/min): Cardiac output
     = SV * HR / 1000
  • CI (l/m/m²): Cardiac Index
     = CO / BSA
  • EF (%): Ejection fraction
     = SV / EDV * 100%
comparison icon
Compare (0)